Voltage +/- 10 V Current 0(4)…20 mA Accuracy 0.01 % (FS) Resolution 16-bit (1 mV / 1 µA) Sampling rate 20 ms / 50 Hz Galvanically isolated fieldbus Electronics protected up to 40 G (option) Vibration resistant up to 4.5 Grms (option) Feldbus CAN Protocol CANopen / Raw CAN
Germany
Equipped with CAN or CANopen interfaces and a 19″ slide-in casing, the MicroControl µLAB is particulary suitable for measuring electric, thermal and mechanic signals in engine or components testing facilities The signal wires are connected to the module by plug-in connectors in the front plate.Current 0(4)…20 mA Accuracy 0.01% (FS) Resolution 16-bit (1 µA) Sampling rate 5ms / 200 Hz Galvanically isolated fieldbus Operating temperatures -40…+85 °C Supply voltage 9…36 V DC Connection via circular plug-in connectors Fieldbus CAN Protocol CANopen / Raw CAN
Request for a quoteGermany
The µCAN.4.sg-BOX is a decentralized measurement data acquisition module for the acquisition of four strain gauges or resistance bridges. The resistance bridge date is acquired at a total sampling rate of 400 Hz.Strain gauge full- / half- / quarter bridge Voltage +/- 60 mV Supply voltage 4.096 V Accurany 0.01 % (FS) Resolution up to 24-bit (1 µV) Sampling rate 5ms / 200 Hz Galvanically isolated fieldbus Anti-aliasing filter Adjustable scaling Protected against mechanical stress Fieldbus CAN Protocol CANopen / Raw CAN
Request for a quoteGermany
The decentralized module µCAN.4.ao-BOX features four analogue outputs which optionally provide a voltage signal (+/- 10 V) or a current signal (0…20 mA). The CAN interface supports the protocols protocols CANopen and J1939.Voltage +/- 10 V Current 0…20 mA Accurany 0.05 % (FS) Resolution 16-bit (1 mV / 1 µA) Signal output 1 ms / 1 kHz Galvanically isolated fieldbus Galvanically isolated analogue outputs Signal type freely configurable adjustable scaling Protected against mechanical stress Fieldbus CAN Protocol CANopen / Raw CAN
Request for a quoteGermany
The µCAN.4.ai-BOX is an extended universal measurement module for the acquisition of analogue standard signals. The device is designed for measuring signals of +/- 10 V, 0…20 mA or 4…20 mA. The CAN interface supports the protocol CANopen.Voltage +/- 10 V Current 0(4)…20 mA Accuracy 0.01 % (FS) Resolution 16-bit (1 mV / 1 µA) Resolution up to 24-bit (0,01 mV / 0,01 µA) Sampling rate 5ms / 200 Hz Galvanically isolated fieldbus Adjustable scaling Signal type freely configurable Protected against mechanical stress Fieldbus CAN Protocol CANopen / Raw CAN